Descargar Imprimir esta página

Miele professional G 8072 Plano De Instalación página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
Water supply
G 8072
Water connection
Shower
(optional)
Waste water
Installationsplan G 8072
Stand: 15.11.2004
4. Art. no.: 61.8072.12
Max. hot water intake temperature
(Boiler heating 9 kW, Tank heating 1.8 kW)
Voltage
Rated load
Fuse rating
Connection cable, min. cross-section
Supply lead, approx.
(plug to be provided on site)
5. Art. no.: 61.8072.03
Hot water intake temperature
(Boiler heating 6 kW, Tank heating 1.8 kW)
Voltage
Rated load
Fuse rating
Connection cable, min. cross-section
Supply lead, approx.
(plug to be provided on site)
Plug and socket connection recommended to facilitate
electrical safety tests. Socket must be accessible after
installation.
On hard-wired machines, a multi-pole circuit breaker with a
minimum contact gap of 3 mm must be provided on site.
Observe correct phase sequence (clockwise).
Supply lead should not be in direct contact with any source of
heat.
Equipotential bonding to be provided for machine and tables!
Connection on frame.
The use of a current-operated ELCB is recommended!
Connection for commercial dishwasher:
Always use hot water where available!
Art. no.: 61.8072.01/02/03/04/
Hot water intake temperature
Art. no.: 61.8072.11/12/13/14
Max. hot water intake temperature
Max. water hardness
G 8072
G 8072 WES
Min. flow pressure
Max. pressure
Throughput
On-site connection thread according to DIN 44 991
Length of connection hose (supplied)
Fit pre-filter (supplied)!
DVGW approved Direct connection without non-return valve
permissible.
Connection for shower:
Min. flow pressure
Max. pressure
Volume flow – Cold/hot water
Connection thread for hot and cold water
(to be provided on site)
Supply hose length for hot and cold water
(supplied)
Max. temperature
Connection (sleeve to be provided on site)
Max. peak delivery
Drain pump head height (from floor)
Length of drain hose (supplied)
Fit odour trap on site!
°C
15-60
V/Hz
AC 230/50
kW
10.7
A
1 × 50
mm²
3 × 10
m
1.5
°C
40-60
V/Hz
3N AC 400-415/50
kW
9.5
A
3 × 16
mm²
5 × 2.5
m
1.5
°C
40-60
°C
15-60
°dH
4
°dH
25
kPa
80
kPa
600
l/min
30
Inch
3/4" ext. thread
m
1.2
kPa
100
kPa
1000
l/min
9
Inch
3/8" ext. thread
m
0.5
°C
85
DN
40 or 50
l/min
50
m
0.65
m
1.0