Descargar Imprimir esta página

Ravelli VELA 7 Serie Manual De Uso Y Mantenimiento página 70

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

AL 04
FUME
Fume exhaust encoder is not working or is
EXHAUST
connected incorrectly
DAMAGED
No power to fume extractor.
The fume extractor is blocked.
AL 05
NO SWITCH-
The pellet tank is empty.
ON
Pellet calibration and suction during switch on
phase
is incorrect.
The ignition coil is faulty or positioned
incorrectly
AL 06
PELLETS
The pellet tank is empty.
FINISHED
The gear motor is not loading pellets.
Not enough pellets loaded
AL 07
RESETTABLE
The manual reset thermostat connected to the
THERMAL
hopper has been triggered
BREAKER
Combustion in the brazier is not optimal due to
clogging or obstructions of internal stove ducts
inside the stove
AL 08
DEPRESSION
The flue is blocked.
The vacuum meter is faulty.
AL 12
FUME
The fume exhaust system has a loss of
EXHAUST
performance due to fan obstruction or voltage
SYSTEM
drop.
AL 14
SCREW
No cable connection to power the gear motor
PHASE
screw
AL 15
SCREW TRIAC
An internal part of the electronic board that
controls the pellet infeed screw is faulty.
Possible voltage drops or incorrect input
voltage
AL 19
CLEANER
The cleaner did not complete the movement
FAILURE
and is not in the correct position
Position of the switch,
protected by the screw cap, for
the safety reset thermostat on
the back of the stove.
Use and maintenance manual Vela 7-9
Contact the Support Service
Contact the Support Service
Contact the Support Service
Check for the presence of pellets in the container.
Top up, if necessary.
Contact the Support Service
Contact the Support Service
Check for the presence of pellets in the container.
Top up, if necessary.
Empty the tank to see if there are any objects inside
that may prevent proper operation of the auger.
Regulate pellets setting from "SET AIR/PELLETS"
If the problem persists, contact the Support Service
Reset the thermostat by pressing the button on the
back of the stove
Switch off the stove, clean the brazier and the tube
bundle and adjust the combustion setting the Pellet/
Air values
Contacter le Service d'Assistance
Check the flue is free and clean
Check the mains voltage.
Check the mains voltage.
Check the mains voltage.
Check the flue is free and clean
Check the mains voltage.
Reset the alarm and wait for the stove to switch to
SHUTDOWN mode. Cut off and power again, the
system reactivates the cleaner searching the correct
position again.
If the problem persists, contact the Support Service
Rev.1 20.02.18
Page 71
EN

Publicidad

loading