INSTRUCTIONS FOR POWER
WARNING: Before servicing this heater be sure to unplug heater from wall outlet. Do
not only turn off heater from the main "ON/OFF" switch, be sure to unplug this heater.
Note: The power cord has a polarized plug (with one blade wider than the other) that will only fit in a
polarized outlet one way. If it does not insert easily try reversing the plug. If it still does not fit contact your
electrician to replace your outlet. DO NOT defeat the safety purpose of the polarized plug.
ELECTRICAL CONNECTION
A 15 AMP, 120 Volt, 60Hz circuit with a
properly grounded outlet is required.
Preferably, the heater will be on a dedicated
circuit. Other appliances on the same circuit
may cause the circuit breaker to trip or the
fuse to blow when the heater is in operation.
The unit comes standard with a 6' (1828mm)
long three wire cord exiting from the rear of
the fireplace.
LEG ASSEMBLY
Four (4) legs
Twelve (12) screws
Tools required: Phillips Screwdriver
Lay stove upside down on a padded surface to avoid scratches to the surface of your stove.
Line up holes in the leg with holes in the underside of the stove body. With the use of the screwdriver secure
leg with the screws provided (3 screws per leg) as shown in the figure below.
WARNING: Electrical
outlet wiring must comply with
local building codes and all
other applicable regulations to
reduce the risk of fire, electrical
shock and injury.
WARNING: Do not use this
fireplace if any part of it has
been under water. Immediately
call a qualified service technician
to inspect the fireplace and
replace any part of the electrical
system if necessary.
WARNING: Do not use this
heater with missing, damaged, or
broken legs.
~ 5 ~