8. commissioning
You receive a fully assembled electro-hydraulic pump as well as detailed operating instructions.
• After receiving the delivery, check it for possible transport damage and the scope of supply for
completeness.
• Should there be any problems, contact the manufacturer or vendor without delay.
• Before commissioning the pump, always read the complete operating instructions
as well as all supplied documents.
caution!
!
there is the risk of injury when lifting the pump in its packaging or by the raised pump falling
(total weight approx. 30 kg).
• Please note the maximum weights that may be lifted by individuals. it may be necessary to
use lifting gear.
• do not stand below the raised pump.
caution!
!
when recommissioning the pump, there is the risk that an improper storage or missing
corrosion protection can lead to danger because of blocked unit components.
• Before recommissioning, ensure the smooth operation of all components as well as the
correct function of all safety equipment (see section 11 "maintenance and inspection").
• Also wear your personal protective equipment for transport and installation of the pump, in particular,
gloves and safety work shoes (see section 2.4 "Personal protective equipment").
• Ensure that the installation surface on which the pump is placed is flat and adequately strong.
• Check the oil level through the side viewing window and, if required, add new HLP 46 hydraulic oil.
note:
in the normal state, the oil level of the hydraulic pump should lie between the "min" - "max"
markings on the side of the pump housing. this ensures adequate hydraulic oil is available to
fill the cylinder and to prevent the pump from running dry when using the associated tools.
• Check the mains cable and plug of the pump for damage. If damaged, do not use the pump!
• Check the hydraulic hose for crushing or other damage. Never use a damaged hydraulic hose.
• Connect the hydraulic hose with the quick-release coupling of the pump and the tool.
note:
there is the danger that hydraulic oil can escape should there be a defective valve or the
hydraulic hose is disconnected under pressure.
• Ensure that the hydraulic system is not under pressure before disconnecting or inserting the
hydraulic hose.
• Before the first use, the sealing screw plug (black) at the tank opening must be replaced with the air
permeable ventilation screw (orange) so that air can flow into the oil tank during work.
21