Descargar Imprimir esta página

Sony VPL-SC60U Manual De Instrucciones página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

Location and Function of Controls
Control panel
0
9
8
7
6
1 I / u (on / standby) key
Turns on and off the projector when the projector is in
the standby mode. The ON/STANDBY indicator lights
in green when the power is turned on.
When turning off the power, press the I / u key
twice following the message on the screen, or press
and hold the key for about one second.
For details on steps for turning off the power, see "To turn off
the power" on page 24 (GB).
2 Indicators
ON/STANDBY: Lights up or flashes under the
following conditions:
• Lights in red when the AC power cord is
plugged into the wall outlet. Once in the standby
mode, you can turn on the projector with the
I / u key on the Remote Commander or on the
control panel.
• Lights in green when the power is turned on.
• Flashes in green while the cooling fan runs after
turning off the power with the I / u key. The fan
runs for about 90 seconds after turning off the
power.
The ON/STANDBY indicator flashes quickly
for the first 30 seconds.
During this time, you cannot turn the power
back on with the I / u key.
10
(GB)
All manuals and user guides at all-guides.com
LIGHT
VOLUME
APA
RESET
I / u
ON
/STANDBY
POWER
INPUT
SAVING
MENU
TEMP
/FAN
LAMP
/COVER
ENTER
POWER SAVING: Lights up when the projector is
in the power saving mode. When POWER
SAVING in the SET SETTING menu is set to
ON, the projector goes into the power saving
mode if no signal is input for 10 minutes.
Although the lamp goes out, the cooling fan keeps
running. In the power saving mode, any key does
not function for the first 30 seconds. The power
saving mode is canceled when a signal is input or
any key is pressed.
TEMP (Temperature)/FAN: Lights up or flashes
under the following conditions:
• Lights up when temperature inside the projector
becomes unusually high.
• Flashes when the fan is broken.
LAMP/COVER: Lights up or flashes under the
following conditions:
• Lights up when the lamp has reached the end of
its life or becomes a high temperature.
• Flashes when the lamp cover or air filter cover is
not secured firmly.
For details on the LAMP/COVER and the TEMP/FAN
indicators, see page 39 (GB).
3 INPUT key
Selects the input signal. Each time you press the key,
the input signal switches between video/audio input
and INPUT A connector.
1
2
3
4
5

Publicidad

loading

Este manual también es adecuado para:

Vpl-sc60eVpl-sc60m