Descargar Imprimir esta página

Hilti TE 60T Manual De Instrucciones página 21

Ocultar thumbs Ver también para TE 60T:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 62
Recommended minimum conductor cross section and max. cable lengths
Conductor cross section
Mains voltage 100V
Mains voltage 110-127 V
Mains voltage 220-240 V
en
Do not use extension cords with 1.25 mm² conductor cross section.
2.12 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this application.
2.13 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled: The unit
must provide a power output in watts of at least twice the value printed on the type identification plate on the power
tool. The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in
the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and
starting boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching other
power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in damage to the
power tool.
3 Insert tools, accessories
Designation
Hammer drill bits
Hammer drill bits
Breach bits
Breach bits
Percussion core bits
Percussion core bits
PCM diamond core bits
Chisels
Chisels
Wood drill bits
Metal drill bits
Designation
Side handle, complete
Depth gauge, complete
Anchor-setting tools
Anchor-setting tools
TPS Theft Protection System with
Company Card, Company Remote
and TPS‑K key
Quick-release chuck
18
1.5 mm²
2.0 mm²
30 m
20 m
30 m
30 m
Short designation
TE 60 / TE 60‑ATC
TE 60T / TE 60T‑ATC
TE 60 / TE 60‑ATC
TE 60T / TE 60T‑ATC
TE 60 / TE 60‑ATC
TE 60T / TE 60T‑ATC
TE 60‑ATC / TE 60T‑ATC
TE 60 / TE 60‑ATC
TE 60T / TE 60T‑ATC
Short designation
TE 60 / TE 60‑ATC
TE 60T / TE 60T‑ATC
2.5 mm²
3.5 mm²
50 m
40 m
75 m
Description
∅ 12...40 mm
∅ 12...40 mm
∅ 40...66 mm
∅ 40 mm
∅ 45...90 mm
∅ 50...90 mm
∅ 42...82 mm
Pointed, flat and shaped chisels with
TE‑Y connection end
Pointed, flat and shaped chisels with
TE‑T connection end
∅ 10...32 mm
∅ Max. 20 mm
Item number, description
330083
366482
Setting tools with TE‑Y connection
end
Anchor-setting tools with TE‑T con-
nection end
206999, optional
For wood and metal drill bits with
smooth or hex. shank

Publicidad

loading

Este manual también es adecuado para:

Te 60-atcTe 60Te 60t-atc