English
Application
Siedle Axiom In-Home, the video
indoor call station with 7" touch-
screen for the Siedle In-Home bus.
With the functions call, speech,
vision, door release, light, storey
call, switching/control functions,
message displays and internal com-
munication.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Electrostatic charging
As a result of electrostatic charging,
direct contact with the circuit board
can result in destruction of the
device. Direct contact with the circuit
board must therefore be avoided.
Remarks
• For use only in dry indoor atmos-
pheres.
• As in the as-delivered/de-energized
status, the contact position of the
bistable relay (contact S1/S1) cannot
be defined, the bus supply to the
device must be connected before-
hand to ensure that the bistable
relay functions correctly.
Scope of supply
• A 150-10 Siedle Axiom In-Home
• Wall mounting plate
• SD card
• Screw-type terminal 6-pin with
holder
• 4-pin screw-type terminal
• This product information
For download
• Operating instructions for the end
customer
Terminal assignment
1,2 = TaM
In-Home bus monitor
3,4 = TbM
branch
0 = ETb
Storey call button
9 = ERT
8 = +M
Supply voltage
20–30 V DC
7 = -M
6 = S1
Potential-free contact
15 V AC, 30 V DC, 1 A
5 = S1
Mounting
1 Recommended mounting height
appr. 1.60 m to display height/
viewing height.
The centre of the display sits 21 mm
above the centre of the double-
device junction box: so with a height
of 1600 mm, the centre of the box
must be set to 1579 mm.
2 Wire up the provided screw-type
terminals according to the terminal
assignment and snap into the wall
mounting plate from behind.
3 When mounting directly on the
wall, fasten the base plate using
4 screws, paying attention that
the plate is the right way up (top
marking). Double device junction
box with an installation depth of at
least 47 mm required.
4 When mounting on a switch box,
use the screw openings in the centre
of the device, paying attention that
the plate is the right way up (top
marking). Double device junction
box with an installation depth of at
least 47 mm required.
5 Snap the panel onto the wall
mounting plate.
Commissioning
• The basic configuration must be
carried out on every device without
fail.
• Installation and commissioning are
described in the Siedle In-Home-Bus
Video system manual. The latest
issue can be found in the download
area at www.siedle.com.
• Functions on the user interface
of Siedle Axiom In-Home can be
individually named. Programming
takes place using the bus program-
ming software (latest version) and is
transferred to the A 150-10 via the
SD card.
Care instructions
Only ever clean your indoor device
using a soft cloth dampened with
mild soap solution. Dry, aggres-
sive cleaning agents and abrasive
detergents can damage the surface.
Detailed care instructions are located
in the download area of www.siedle.
com.
Specifications
Operating voltage: 20–30 V DC
Operating current: max. 400 mA
Contact type: potential-free S1/
S1 max. 15 V AC, 30 V DC, 1 A
switching time 0.4 sec - 19 min
Ambient temperature:
+5 °C to +40 °C
Dimensions (mm) W x H x D:
185 x 144 x 18
5