To access the programming menu of the special functions you need to:
1. Disconnect ARM and FOG
2. Note down the DIP-SWITCH configuration
3. Turn all DIP-SWITCH OFF
4. Remove the Jumper from BUZZ (J3)
5. Place the Jumper on J2
6. Set the DIP-SWITCH No. 10 to ON
7.
T
urn ON all DIP-SWITCHES of the functions you want to be activated
8. Remove the Jumper from J2 and replace it on BUZZ (J3)
9. Restore the DIP-SWITCH as noted down before (point 2)
If you want to use the special functions of the Menus 1 and 2 you will have to program them
simultaneously.
DIP1
OFF
AND FOG + FOG2
FUNCTION
ON
SHOOTING LOCK
X
FUNCTION
X
SEPARATE SHOT
X
FUNCTION
X
X
STATE RELAY H24
N.C.
X
X
AUTOMATIC
ARM/DISARM
X
X
AUTO-ARM BY
NEGLIGENCE
X
X
ALARM IN
FUNCTION
X
X
ARM/DISARM
WITH IMPULSE
X
Note: Enabling the " AUTOMATIC ARM/DISARM " or " AUTO-ARM BY NEGLIGENCE" functions the "ARM/DISARM WITH
IMPULSE" function is also automatically activated.
EVERY TIME YOU ENTER IN THIS MENU, THE SPECIAL FUNCTIONS ARE RESTORED TO THE FACTORY
VALUES, so if for example we have used 2 special functions and we have changed our mind on one of
these, entering in the menu again we will only need to reactivate the function that we intend keep (the
other one will be deactivated automatically).
It is possible to check the status of the special functions using the DT-FogControl software
SPECIAL FUNCTIONS - MENU 2
(ENTER MENU '1 AND PROGRAM DIP 10 = ON)
DIP2
DIP3
DIP4
X
X
X
X
X
X
OFF
X
X
ON
X
X
X
ONLY
X
DT.1600L
X
X
X
X
OFF
X
X
ON
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
DIP5
DIP6
DIP7
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
OFF
X
X
ON
X
X
X
OFF
X
X
ON
X
X
X
OFF
X
X
ON
X
X
X
X
X
X
CAUTION!!!
15
DIP8
SETTING
X
DISABLED FUNCTION
X
"AND FOG+FOG2" ACTIVATED
X
DISABLED FUNCTION
X
ENABLED FUNCTION
X
DISABLED FUNCTION
X
ENABLED FUNCTION
X
NO H24 LOGIC
X
OPEN WHEN A FAILURE OCCURS
X
DISABLED FUNCTION
X
ENABLED FUNCTION
X
DISABLED FUNCTION
X
ENABLED FUNCTION
X
DISABLED FUNCTION
X
ENABLED FUNCTION
OFF
DISABLED FUNCTION
ON
ENABLED FUNCTION