REPORTING OF THE OPERATING AND FAILURE
TURNED ON STEADILY
ARMED
LED1
HEATING
TURNED ON STEADILY
LED2
SHOT
TURNED ON STEADILY
LED3
WASH
TURNED ON STEADILY
LED4
FORCED PAUSE
TURNED ON STEADILY
LED5
FAILURE
LED6
(RED)
SOUND SIGNALING OF A FAILURE
When a failure occurs, the appliance will emit 10 beeps and repeat the signal every 60 min. until it
will be restored.
Note: In case of "self-resetting" faults (battery or 220V absent) the sequence of the 10 Beeps may
stop earlier, so if the signals are irregular in the Beep number or the repetition, it means that we
are in the presence of a "false contact" on the battery or on the 220V mains.
STATUS VIA LED
ARMED APPLIANCE
SLOW FLASHING
DISARMED APPLIANCE
DISARMED APPLIANCE BUT WITH ACTIVE BURNER PREHEATING
FAST FLASHING
FUNCTION (50% of maintenance)
TURNED OFF
ALL THE RESISTANCES OFF
ALL THE RESISTANCES SELECTED ON
ONLY ONE RESISTANCE ON; THE NUMBER OF FLASHES =
CODED FLASHING
RESISTANCE NUMBER
TURNED OFF
SHOT NOT ACTIVE
SHOT ACTIVE
ONE FLASH
TO EVERY REARMAMENT OF THE MACHINE
TURNED OFF
BURNER WASH NOT IN FUNCTION
BURNER WASH IN FUNCTION
ON FLASH
TO EVERY REARMAMENT OF THE MACHINE
TURNED OFF
THE APPLIANCE IS NOT IN THE FORCED PAUSE STATE
THE APPLIANCE IS IN THE FORCED PAUSE STATE
(it will ignore every firing commands untili its end)
ONE FLASH
FOR EVERY RIARMAMENT OF THE MACHINE
TURNED OFF
NO ALLARM
N. 1 FLASH: LIQUID_LEVEL_ALARM
N. 2 FLASH: CARD_OVERHEATING_ALARM
N. 3 FLASH: BATERY_ABSENT_ALARM
N. 4 FLASH: DEFECTIVE_SONDE_ALARM
CODED FLASHING
N. 5 FLASH: LACK_ELECTRICITY_ALARM
N. 6 FLASH: BURNER_OVERHEATING_ALARM
N. 7 FLASH: FAULT_PUMP_ALARM
N. 8 FLASH: FAULT_RESISTANCE_ALARM