Precautions for Use
This air conditioner must be installed properly by qualified
z
installation technicians in accordance with the Installation
Instructions provided with the unit.
Before installation, check that the voltage of the electric sup-
z
ply in your home or office is the same as the voltage shown
on the nameplate.
Avoid the following locations for installation.
Locations where smoke or combustible gas exists.
z
Also locations of extremely high temperature such as a
greenhouse.
Locations where excessively high heat-generating ob-
z
jects are placed.
Attention:
Avoid installing the outdoor unit where salty sea water can
z
splash directly onto it or in sulphurous air near a spa.
(To protect the air conditioner from heavy corrosion)
All wiring must conform to the local electrical codes.
z
(Consult your dealer or a qualified electrician for details.)
Each unit must be properly grounded with a ground (or
z
earth) wire or through the supply wiring.
Wiring must be done by a qualified electrician.
z
Operation Preparation
Turn the power mains on 5 hours before
the start of operation.
(For warm-up)
Leave the power mains ON for continuous use.
z
NOTE
Pull off the power plug from a receptacle, or switch off the
breaker, or switch off the power disconnecting mean to isolate
the air conditioner from the main power supply when not in use
for a long time.
4
Installation
WARNING
Wiring
Operation Condition
Use this air conditioner under the following temperature range.
Outdoor Unit
2WAY (Type ME2)
Cooling
14°C 25°C (*WBT)
Heating
16°C 30°C (*DBT) -25°C 18°C (*WBT)
*DBT: Dry bulb temperature
*WBT: Wet bulb temperature
*1: The maximum allowable temperature of this air conditioning
system is reduced to 43°C when using the existing R22 pipe.
ON
Indoor
Outdoor
temperature
temperature
range
range
-10°C 52°C (*DBT)
-10°C 43°C (*DBT)*1

Publicidad

loading