Descargar Imprimir esta página

Emerson AVENTICS ST6-SM Instrucciones De Montaje página 18

Sensor de medición de recorrido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
2
11 V
10 V
Fig. 6: Analog position output
1 Zero point / physical zero position
3 Negative positions
5 Piston position
6 Assembly and installation
Before you start with the installation: Familiarize yourself with the basic specifica-
tions for assembly as early as possible in advance. See
g 6.2 Preparation.
6.1 Planning
6.1.1 Installation conditions
General requirements
• Make sure that the product is installed in a manner that protects it from all
types of mechanical loads.
• Make sure that there is sufficient space.
Product-specific requirements
• Mounting orientation. See
g 14. Technical
Ambient conditions
• Keep the installation location free from vibration.
• Protect the product from direct sunlight and UV radiation.
• Make sure that there are no ferromagnetic sources near the product (material
protection).
6.1.2 Required accessories, materials and tools
Select material and tools that are suitable for your product configuration. De-
pending on the configuration, you will need further accessories.
Mounting material
For mounting, you can use your own mounting material or AVENTICS mounting
material. Respect dimensions and tightening torques.
Tools
• 1x non-magnetizable hex key (size 2.5)
INFO: Size 2.5 corresponds to AF2.5 on the packaging.
6.2 Preparation
6.2.1 Unpacking and checking the product
1. Check the material number to see if the product matches your order.
2. Check the product for transport and storage damage.
Do not install a damaged product. Return damaged products together with
the delivery documents. See
3. Prepare required accessories, materials and tools.
AVENTICS™ ST6-SM | R412028907-BAL-001-AA | English
1
3
0
10.5 V
4
5
0 V
6
2 Positive positions
4 Sensor detection range: 0 ... 10 V
(analog output)
6 Sensor position output
g 6.1 Planning
data.
g 4.3 Returning the
product.
6.2.2 Notes
• Insulate the wire ends against each other. When the supply voltage is
switched on, there is a risk of short circuits if open wire ends touch each other.
• Wire cross-sections of the supply line provided by the user must be in accor-
dance with IEC 60364-1 and IEC 60364-5-52.
6.2.3 Implementing safety measures
Procedure
1. Do not carry out any work on the system during preparation.
2. Close off dangerous areas.
3. Make sure the system or system part is not under pressure or voltage.
4. Protect the system against being restarted.
5. Allow product and adjacent system parts to cool down.
6. Wear PPE.
6.2.4 Software installation
1. Download the IODD file with the production date of the product in its file
name. See product page in the Emerson store.
2. Install IODD files.
6.3 Mounting the product
Notes
• The triangles on the product indicate the location of the physical zero posi-
tion.
Procedure
and
Insert the product into the T-slot in the centre of the magnet's travel range.
u
ð Analog output provides a value of 2 V...8 V.
Tighten the screw.
u
Tightening torque: 0.7 Nm
1
Fig. 7: Mounting the product
6.4 Connecting the electrical system
Notes
• Circuits connected to the product must be SELV and PELV circuits.
• Use a power source in compliance with EN 60204-1.
6.4.1 Connecting the supply voltage
Connect the product according to the pin assignment. See
u
rameters.
6.4.2 Wiring the lines
Procedure
Table 1: Power groups of the cables with regard to interference immunity / inter-
ference emission
Power group
1
2
3
4
1. Ensure that the sensor is properly aligned in the axial direction.
2
3
Description
Very interference-sensitive lines
Interference-sensitive lines
Interference sources
Strongly interfering lines
4
g 11. Data and pa-
Example
Analog measuring lines
Sensor line, communication signals,
bus signals
Control line for inductive loads and
motor brakes
Output cable of frequency convert-
ers, supply of welding equipment,
power cables
18