ARc W
SETUP FOR STICK (MMA) PROCESS
PLUG
ground clamp cable into negative socket and twist clockwise to lock in place
PLUG
electrode holder cable into positive socket and twist clockwise to lock in place
ENSURE
the ground cable has a good connection to workpiece and is connected on clean, bare metal
CLEAN
weld surfaces with brush or grinder until no rust, paint, oil, or other materials remain on weld surfaces
ATTACH
ground clamp to bare metal on the workpiece or to metal work bench where workpiece is clamped
PRESS
the switch to set the ARC (MMA) welding process
SET
electrode holder down on nonconductive nonflammable surface away from grounded objects
TURN
power switch on
ADJUST
the amperage control knob to desired settings
ELECTRODE SELECTION
6010
INDUSTRIAL
DIRTY METAL
See www.ktindustries.net for detailed specifications and guidance of electrode selection.
Material
Mild Steel
Stainless Steel
Aluminum
Start by setting recommended amperage and adjust as necessary.
ELdiNg
6011
6013
GENERAL
STICK (MMA) WELDING SET-UP CHART
Electrode type
E6010
E6011
E6013
E6014
E7018
E308L
Not Suitable for Aluminum Welding
www.ktindustries.net
PAGE | PAGE | PÁGINA
7014
SPEED OF TRAVEL
Electrode Diameter
1/16" (1.6mm)
5/64" (2mm)
-
30-40A
40-60A
-
-
9
7018
LOW SPLATTER
3/32" (2.4mm)
-
50-70A
50-70A
-
70-80A
-
40-70A
®
®