Hazard information
Please only connect ohmic and capacitive lamp loads to the dim-
R,C
ming actuator, and no televisions, computers, motors etc.
Do not connect LED or compact fluorescent lamps which are not
expressly suitable for dimming. Device may be damaged.
No SELV/PELV power circuits may be connected to the connecting
terminals of the dimmer output.
Do not connect lights with integrated dimmer. Device may be da-
maged.
For operation with electronic ballasts, only transformers that on the
requirements of DIN EN 61347-1 and DIN EN 61047 may be used.
When connecting to the device terminals, take the permissible ca-
bles and cable cross sections into account.
Loads connected to the relay outputs require sufficient insulation.
Please take the technical data (in particular the maximum permissi-
ble switching capacity of the relay and the type of load to be con-
nected) into account before connecting a load. All load data relates
to ohmic loads. Do not exceed the capacity specified for the device.
No SELV/PELV power circuits may be connected to the connecting
terminals of the relay outputs.
Exceeding this capacity could lead to the destruction of the device,
fires or electric shocks.
The circuit to which the device and the load will be connected must
be protected by a circuit breaker in accordance with EN60898-1
(tripping characteristic B or C, max. 16 A rated current, min. 6 kA
breaking capacity, energy limitation class 3). Installation regulations
30