GB
PROBLEM
THE ELECTROPUMP DOES
NOT PUMP WATER, THE MO-
TOR DOES NOT RUN
THE MOTOR RUNS BUT THE
ELECTROPUMP DOES NOT
PUMP LIQUID
THE ELECTROPUMP STOPS
AFTER RUNNING FOR A PE-
RIOD OF TIME BECAUSE ONE
OF THE THERMAL MOTOR
CIRCUIT BREAKER TRIPS
If the problem cannot be eliminated after carrying out the above-described operations contact the closest service centre.
8
POSSIBLE CAUSE
1) No power.
2) Motor protection tripped.
3) Defective condenser.
4) Shaft blocked.
1) The pump is sucking air.
2) The pump rotates in the wrong
direction
3) Suction grid blocked.
4) Check valve blocked.
1) The power supply does not con-
form with the data on the nameplate.
2) A solid object is blocking the
impellers.
3) The liquid is too thick.
GB
1) Check the presence of voltage and if the plug is plugged
in properly.
2) Verify the cause and reset the switch. If the thermal
circuit
breaker has tripped wait for the system to
cool down.
3) Replace the condenser.
4) Verifi care la causa e sbloccare l'elettropompa
1) Check:
a) that the joints are sealed
b) that the level of the liquid has not gone below the
minimum priming level
2) Reset the direction of rotation.
3) Clean the fi lter
4) Clean or replace valve.
1) Check the voltage on the power supply cable leads.
2) Take the electro-pump apart and clean it
3) Change the type of electropump.
4
REMEDY