Ch. 2 Limitations
Technical Data
Mains voltage / Frequency
Absorbed power
Type of protection / Insulation class
Delivery fi tting
Maximum fl ow rate
Maximum head
Maximum immersion depth
Power cable
Weight
Maximum dimension of pumped solid particles
Maximum admitted working pressure
Maximum amount of sand
Minimum diameter of the well
Maximum temperature of the pumped fl uid
Maximum number of starts per hour
Technical Data
Mains voltage / Frequency
Absorbed power
Type of protection / Insulation class
Delivery fi tting
Maximum fl ow rate
Maximum head
Maximum immersion depth
Power cable
Weight
Maximum dimension of pumped solid particles
Maximum admitted working pressure
Maximum amount of sand
Minimum diameter of the well
Maximum temperature of the pumped fl uid
Maximum number of starts per hour
Sound pressure level: less than 70 dB (A) - sound emission values obtained in conformity with the EN 12639 standard
Eventual malfunctions caused by the presence of sand in the pump are not covered under warranty as this can be
attributed to the transfer of more than 50g/m
Ch. 3 INSTALLATION
Avoid using the electric cable to lift or transport the pump. Use a stainless steel or nylon rope, suitable to sustain
the weight, to immerse the electropump. Two slots are present for allowing the anchoring of the head of the electro-
pump. Anchor the rope so that it balances the weight of the electropump.
It is advisable to connect the electric cable to the delivery with plastic straps, at a distance of about 3 m, when
using rigid piping.
It is also advisable to fi t automatic level controls to prevent the electropump from running without liquids and a
pressure gauge (suitable to the electropump model) to verify its performance during operation.
6
The electropump cannot be used to move infl ammable or
WARNING
dangerous liquids.
WARNING
Verify that the electropump never runs without liquids.
3
of sand as indicated in the table.
All the operations that concern the installation must be carried out
DANGER
with the pump disconnected from the energy supply.
Electric
Pumps in this series are not suitable for use in a swimming pool and
shock risk
the relevant cleaning and servicing operations.
GB
6
SUB
S
230-240 V ~ 50 Hz
800 Watt
IP 68 / F
41,90 mm (1"1/4 F)
3.300 l/h
50 m
19 m
22 m H07 RNF
12 Kg
≤ 1 mm
11 bar
50 gr/m
3
100 mm
40° C
30, uniformly distributed
4600/75
SUB
230-240 V ~ 50 Hz
1100 Watt
IP 68 / F
41,90 mm (1"1/4 F)
4.600 l/h
75 m
27 m
30 m H07 RNF
12,5 Kg
≤ 1 mm
11 bar
50 gr/m
3
100 mm
40° C
30, uniformly distributed
2
8
SUB
S
230-240 V ~ 50 Hz
1100 Watt
IP 68 / F
41,90 mm (1"1/4 F)
6.000 l/h
57 m
19 m
22 m H07 RNF
13 Kg
≤ 1 mm
11 bar
50 gr/m
3
100 mm
40° C
30, uniformly distributed
6000/75
SUB
230-240 V ~ 50 Hz
1300 Watt
IP 68 / F
41,90 mm (1"1/4 F)
6.000 l/h
71 m
27 m
30 m H07 RNF
12,5 Kg
≤ 1 mm
11 bar
50 gr/m
3
100 mm
40° C
30, uniformly distributed

Publicidad

loading

Este manual también es adecuado para:

Sub 6000/75Sub 6sSub 8s