Insert the insulated grounding wire (G) into the lug
below the terminal block.
10. Insert stripped end of white wire (W)into the center lug.
11. Secure the clamping screw.Insert the stripped end of
the red wire (R) into the left lug. Secure clamping
screw.
12. Insert the black wire (B)into the right lug. Secure the
wire in place using the lug clamping screw.
13. Tighten each clamping screw with the appropriate
torque (see table).
Gauge
Torque (in/Ibs)
Torque (Nm)
6
35
3.95
8
25
2.82
14. Properly secure flexible conduit at knockout on angle
and at supply side junction box. The wiring is now
complete.
Note: DO NOT plug in range at this time.
Three Wire Flexible Conduit Connection
The Four Wire Connection is preferred, but where local
codes and ordinances permit grounding through neutral
and/or conversion to four wire is impractcal, unit may be
connected to the power supply via a three wire connection
1.
Disconnect electrical power at the breaker box.
2.
Remove the terminal block cover to expose the
terminal block.
3.
3. Remove the top nut, star washer, and round washer
from each post.
Note: DO NOT remove last round washer, last nut or inter-
nal wire leads.
4.
Place one terminal lug (packaged with this manual) on
each post. Replace the star washer and round washer
and secure with 20" (50.8 cm) pounds of torque.
5.
Strip 3/8" (9.5 mm) of insulation om the end of each
wire.
3/8 '_
6.
Insert stripped end of white wire into the center lug on
top of the ground strap. Secure the clam-ping
screw.
A
B
English 13