Fire door opening-closing
handle;
- Opening: clockwise
- Closing: anticlockwise
1.5 Permissible use and fuel
The pellet stoves work exclusively on pellets in different types of wood complying with Standard DIN plus 51731 or
UNI EN ISO 17225-2 or Ö-Norm M 7135 or having the following characteristics:
Heat value
Density
Moisture
Diameter:
Ash percentage
Length:
Composition:
Packing
The pellet hopper is at the back of the stove.
The door is located in the top part and loading occurs manually with the stove on or off, making sure not to overfill
and operate in complete safety.
The use of pellets with characteristics different from those tested by the technician during first lighting involves a
new setting of the boiler pellet loading parameters; this operation is not covered by the warranty.
- Store the pellets in a dry place.
- For reasons of regular and efficient operation, pellets or other fuels cannot be manually loaded in the brazier.
- Do not load non-conforming fuels in the hopper.
- Do not load foreign bodies such as containers, boxes, bags, metals, etc., in the hopper.
- The use of poor quality and non-conforming pellets damages and compromises stove operation,
invalidating the warranty with the exclusion of liability of the manufacturer.
1.6 Accessories supplied
The supply includes:
Installation, use and maintenance manual;
Fire door opening - closing key;
Remote Control.
1.7 Reference standards
Standard UNI 10683:2012 :
Standard UNI EN14785:2006 :
Standard CEI EN 60335-1 :
Standard CEI EN 60335-2-102 : Safety of electrical appliances for domestic and similar use - part 2;
Standard CEI EN 55014-1:
min. 4.8 kWh/kg (4180 kcal/kg)
680-720 kg/m3
max. 10% weight
6 +0.5 mm
max. 1.5% weight
min. 6 mm- max. 30 mm
100% untreated wood from the wood industry or post consumer without added binding
substances or bark, complying with current regulations
in bags made from environmentally friendly or biodegradable material or paper
Installation requirements for heat generators burning wood or other solid biofuels;
Requirements for design, manufacture, construction, safety and performance,
instructions and marking, together with the relevant test methods for approval of
units burning pellets;
Safety of electrical appliances for domestic and similar use - part 1;
Electromagnetic resistance - Requirements for electrical appliances, electric tools
and similar electric equipment - Part 1: Emission of interference;
To open the door, fit the handle
supplied and turn it clockwise
27
EVA-2016