Note: Some cabinet finishes cannot survive the
temperatures allowed by safety standards, particularly self-
cleaning ovens; the cabinets may discolor or stain. This is
most noticeable with laminate cabinets.
Avoid obstructing
air flow
WARNING
Risk of fire - do not obstruct the vent space at the
rear of the range top. Do not caulk or otherwise seal
this opening.
Proper vent spacing for the Dual Fuel or Gas ranges is
automatically achieved when the rear of the range is
against the wall. If the resulting gap is obstructed, even
temporarily, the range and/or the surrounding cabinetry
could overheat, creating a fire hazard.
measurements in inches (mm)
* Minimum clearance of 30" required to
overhead combustible surface.
if installing overhead vent or over-
the-range microwave, refer to clearances
provided with these products.
Flame retardant materials bear the mark:
UNDERWRITERS
LABORATORIES
INC. CLASSIFIED
MINERAL AND FIBER BOARDS SURFACE BURNING
CHARACTERISTICS,
followed by the flame spread and
smoke ratings. These designations are shown as "FHC
(Flame Spread/Smoke Developed)". Materials with "0"
flame spread ratings are flame-retardant.
Local codes may
allow other flame spread ratings. It is the responsibility of
the installer to ensure installation is in accordance with
these ratings.
Prepare Walls and Floor
Seal any holes in the walls or floor. Remove any ob-
structions (extra electrical or gas connections, etc.) so that
range will rest against wall properly.
Countertop Requirements
Countertops must be smooth and level.
English 6
9001079089 Rev A