hose that delivers steam to the iron steam wand/nozzle. This prevents water
leakage (the steam iron must always be held in such a way as not to harm the
operator.
4.
To adjust steam flow, regulate the steam adjustment tap (fig. 5/7.1: solenoid
valve).
5.
The Boiler is now ready for use. During use, the "steam ready" pilot light
switches on and off (C).
ATTENTION: Make sure that water is always available for the steam generator, the
lack of water can cause air bubbles inside the conduit, i.e. the water will not reach
the Boiler while the Boiler is under pressure. Without water, the pump will function
for about a minute; after that the alarm will sound and will cause the automatic
shut down of the entire unit.
6.
Water pressure should never go over 3.5 lbs, otherwise the pump will stop
and, accordingly, the water will not reach the Boiler.
CONNECTION TO THE WATER TANK
1.
The Boiler is designed to be connected to a direct waterfeed. If a direct water-
feed source is not available a water container kit is available.
*IF USING THE WATER CONTAINER KIT ENSURE THAT THE VALVE TO THE DIRECT FEED IS IN THE CLOSED POSITION.
2.
To assemble the kit please proceed as follows:
Open the front panel unscrewing the 4 screws.
Insert the silicon hose on the valve MC111 and place the opposite end
into the water tank.
Insert the other silicon hose on the water inlet (1), placing the other end
into the water tank.