Entering/Exit to the settings sub menu
Disconnect the power cable from the wall socket. Wait a few seconds. Press
and hold the knob and connect the power supply again. Keep holding down the
button fore more than 3 seconds.
The sub menu have following settings. Turn clockwise to navigate through
the menu.
P1 = Backlight ON-OFF-Automatic
P2 = Backlight brightness
P3 = Time format 0-24h or 12AM-12PM
P4 = Temperature format °C or °F
P5 = Calibration of temperature sensor offset
P6 = Cool down time for HPS/MH lamps
P7 = Output signal 0-10V or PWM (pulse width modulation)
P8 = Maximum value of the output signal
P9 = Minimal value of the output signal
P10 = Sunrise in minutes for 0-10V/PWM
P11 = Sunset in minutes for 0-10V/PWM
P12 = Reset to factory settings
P13 = End return to main screen
P1 - Back-light settings
Push the knob once the value start to blink and you can change the value.
Choose between Automatically, ON, OFF. Push again to save the settings and
return to the sub menu. (default is Auto.)
Repeat for all other settings. Turn clockwise once to go to the next
parameter, push to enter the settings, rotate to change the values, push again to
save.
P2 - Choose the brightness of the green backlight. 0-20 (default is 20)
P3 - Change the Time format from 0-24h or 12AM-12PM (default is 0-24h)
P4 - Change the Temperature format from degree Celsius to degree Fahrenheit
(default is °C)
P5 - Here you can adjust the value of your temperature sensor and enter a offset
value. Example. you measure and display 24°C but you like to have 24.5 °C. Add
+0.5. It will display the 24°C + 0.5°C and display 24.5°C on your main screen.
P6 - If you use HPS/MH lamps you can avoid to switch ON during hot condition.
The time you set here is the minimum interval between the last switch off and the
next switch ON. It is mostly used in combination with your Start and Stop function
by temperature.