5.3
Instructions for installation
5.3.1 Size of work surface cutout area
Cut out the work surface according to the dimensions indicated in the drawing. For installation and use,
a minimum space of 50 mm (X) must be maintained around the cutout as shown in the illustration.
The thickness of the worktop must be at least 30 mm. To avoid deformations of the work surface that
could be caused by heat radiating from the hob, use heat-resistant material. Use the sealing tape as
shown in the illustration.
WARNING: The work surface material should be made of impregnated wood or other
insulating material.
H
X
B
L (mm)
W (mm)
590
520
WARNING: Make sure that the induction hob is well ventilated and that the air inlet and
outlet are not blocked.
Make sure the induction hob is always in good condition.
en-38
sealing tape
L
D
X
H (mm)
58
X
D (mm)
A (mm)
54
560
W
A
B (mm)
X (mm)
490
50 minimum
X
Fig. 5.1