Store the nose adapter in place when not in use. The
place for storage is on both sides of the tool and inside
the carrying case.
1
2
Connecting air hose
1
Slip the air socket of the air hose onto the air fitting on
the nailer. Be sure that the air socket locks firmly into
position when installed onto the air fitting. A hose cou-
pling must be installed on or near the tool in such a way
that the pressure reservoir will discharge at the time the
air supply coupling is disconnected.
OPERATION
To drive a nail, you may place the contact element
against the workpiece and pull the trigger.
CAUTION:
WITH THE TRIGGER HELD IN A HALF-PULLED
POSITION, an unexpected nailing could occur, if
contact element is allowed to re-contact against the
workpiece or the other surface under the influence
of recoil.
In order to avoid this unexpected nailing, perform
as follows;
A. Do not place the contact element against the work-
piece with excessive force.
007186
1. Nose adapter
2. Place for stor-
age
007187
2
1. Air fitting
2. Air socket
007188
B. Pull the trigger fully and hold it on for 1-2 seconds after
nailing.
Direction of exhaust air
The direction of exhaust air can be changed 360 degrees
of angle by turning the exhaust cover with a hand.
Removing nails
CAUTION:
Do not use deformed nails or nail strip. Failure to do
so causes poor nail feeding.
WARNING:
Always disconnect the hose before removing nails.
Open the slide door and remove nails from the maga-
zine.
With the slide door kept open, open the door and take
out nails.
Removing the contact top allows nails to be easily taken
out. When re-installing the contact top, insert the proru-
sion of the contact top into the notch in the contact arm.
1
6
007189
1. Exhaust cover
1
007190
007191
1. Latch