Display / Control Panel - Hazet-Werk 7000 sTAC Serie Instrucciones De Uso

Llave dinamométrica / medidora de ángulos de giro electrónica
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 67
The lower the target value and the tolerance value, the
quicker the second signal level is exceeded.
• The third signal level – red flashing light, acoustic signal
and high-frequency vibration – indicates that the applied
torque is above the target value range. If the third signal
level is reached, the applied torque is too high. Stop the
screw action. Proceed in line with the instructions for
this screw-joint: e.g. undo the screw and re-tighten it, or
replace it with a new one.
• The fourth signal level – permanent red light, permanent
acoustic signal and permanent vibration – indicates that
the applied torque is above the maximum permissible
torque range of the torque wrench with built-in angle
gauge. If the fourth signal level is reached, the screw action
must be aborted immediately. Failure to comply with these
instructions can result in (irreparable) damage to the torque
wrench with built-in angle gauge.
• If no further torque or rotation angle is applied after activa-
tion, the display alternates between the maximum value of
this action and an OK/Not OK message.
• The "Torque track" program displays the torque currently
being applied without specification of a target value or a
tolerance on the display. In this program, only the fourth
signal level is activated when the maximum permitted
torque value has been reached. The highest torque value
for this process (without validation) is displayed when no
more force is being applied.
• The torque wrench with built-in angle gauge can be pro-
gramed with "Direction of rotation: right (+)" and "Direction
of rotation: left (-)" in the "Torque peak" and "Rotation
angle" programs.
NOTE! In "Torque track" and "Peak" mode, the screw
action stops after 2 seconds if no torque is applied dur-
ing this time. In "Rotation angle" mode, the screw
action stops after 4 seconds if no torque is applied
during this time.
• Every screw action is stored in the memory with a cor-
responding date and time.
• Pressing a key rotates the display (in order to read the
display regardless of direction of actuation).
• The torque wrench with built-in angle gauge switches off
automatically after the set "stand-by" time when it is not
being used.
• If necessary, a rotation angle check for torque tightening
and a torque check for rotation angle tightening can be
programmed in order to check the screw action and con-
nection. If a check function is programed, the second signal
level is only activated and the screw action is only evaluated
as OK if the relevant target value and check ranges overlap
with one another at the end of operation.
• The "Parameters" menu option allows you to save pro-
grams for various screw-joints. Activating a workflow ena-
bles these screw-joints (parameters) to be completed one
after another. The wrench display indicates the progress
of the workflow.
22
Design and function
Signals table:
Signal levels
Level 1 (threshold value)
Yellow flashing light, acoustic signal
and
low-frequency vibration
Level 2 (within target value range)
Green flashing light, acoustic signal
and mid-frequency vibration
Level 3 (above target value range)
Red flashing light, acoustic signal
and high-frequency vibration
Level 4 (above max. torque)
Permanent red light, permanent
acoustic signal
and permanent vibration
Yellow light flashes once
on reaching the snug torque
start of angle measurement

4 . Display / Control panel

Torque unit
Battery display
if applicable with
degree (/°) - Display
Effective length
Memory display
+
(or direction of rotation, snug torque and rotation angle)
Torque
Rotation
Peak
Track
angle
v
v
v
v
v
v
v
v
v
v
Tolerance
Direction of rotation and
Torque target value

Publicidad

Tabla de contenido
loading

Tabla de contenido