Descargar Imprimir esta página

IPC Gansow CT40/ECS Manual De Instrucciones página 80

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 168
5.4.
Electrical connections and earth (cable models)
The electrical characteristics of the machine are given on the rating plate (fig. 1). Make
sure the frequency and voltage correspond to those of the mains supply where the
machine will be operated. As far as voltage is concerned, models where the rating plate
specifies a voltage of 230 V can be used with voltages of between 220 V and 240 V.
Similarly, models rated at 115 V can be used at between 110 V and 120 V. The frequency
on the plate must always correspond to the mains voltage.
Make sure the mains circuit is suitably earthed and that the sockets (and any
adaptors used) ensure the continuity of the earth conductors.
Failure to observe these instructions could cause possibly serious damage to
5.5.
Power supply batteries (battery models)
Two different types of battery may be installed on these machines:
• tubular leak-proof batteries: the electrolyte level must be checked regularly. When
necessary, top up with distilled water until the plates are covered. Do not overfill (5 mm
max. above the plates).
• gel batteries: this type of battery requires no maintenance.
The technical characteristics must correspond to those indicated in the paragraph on the
technical specification of the machine. The use of heavier batteries could seriously
jeopardise manoeuvrability and lead to the brush motor overheating. Batteries with a
lower capacity and weight will require recharging more frequently.
They must be kept charged, dry and clean and the connections must be tight.
Follow the instructions below to set the type of battery installed on the machine's
software.
Mechanical drive version (B):
1. turn the machine on by pressing the button (fig. 6, ref. 3), wait 5 seconds and
make sure the display comes on.
2. press the brush buttons (fig. 6, ref. 3) and suction button (fig. 6, ref. 2) together for
at least 5 seconds. This accesses the battery setting menu.
3. press the suction button (fig. 6, ref. 2) to select the type of battery installed on the
machine "ACd" for acid batteries (tubular leak-proof batteries) or "GEL" (GEL
batteries).
4. memorise the displayed parameter by pressing the button (fig. 6 ref. 3).
Electric drive version (BT): set the machine software to the type of battery installed,
following this sequence:
5. turn the machine on by turning the key switch (fig. 6, ref. 15), wait 5 seconds and
make sure the display comes on.
6. press the brush buttons (fig. 6, ref. 3) and suction button (fig. 6, ref. 2) together for
at least 5 seconds. This accesses the battery setting menu.
7. press the suction button (fig. 6, ref. 2) to select the type of battery installed on the
machine "ACd" for acid batteries (tubular leak-proof batteries) or "GEL" (GEL
batteries).
8. memorise the displayed parameter by pressing the emergency button (fig. 6 ref.
15).
ENGLISH
10
IMPORTANT
! DANGER
people and things and invalidates the guarantee.
INFORMATION

Publicidad

loading