The lights and the fan motor should be switched 'OFF' to set the timer.
Push the LED button '-' until the LED lights will flash :
One flash of the LED lights 2,3, and 4 = function is switched 'OFF'.
Two flashes of the LED lights 2,3, and 4 = function is switched 'ON'.
While the 5 minutes timer is running, It is available to stop immediately the boost speed by pressing the
led button 5.
While the 5 minutes timer is running, the indication of saturation of the filters is switched 'OFF'.
If a pre-set stop for the hood is switched 'ON' and the 5 minutes timer is still running, the boost speed will
be switched 'OFF' together with the pre-set stop for the hood after the count down of 5, 10 or 15 minutes.
It is available to stop the boost speed before the count down of the preset stop of the hood by pressing
the led button 5.
• Pre-set stop for the hood :
This function allows you to program the cooker hood to automatically stop cooking after a pre-set period.
The lights and the fan motor should be switched 'OFF' to set the timer.
Proceed by repeatedly pressing the LED button 5 (Boost speed):
Two flashes of the LED button 1 & 5 = 5 minutes delay.
Three flashes of the LED button 1 & 5 = 10 minutes delay.
Four flashes of the LED button 1 & 5 = 15 minutes delay.
One flash of the LED button indicates the function is switched 'OFF'.
You can switch the cooker hood 'ON' and adjust the speed. The LED buttons 2, 3 and 4 will flash to
indicate the fan motor is switched 'ON' and which speed has been selected.
One flash = stop after 15 minutes.
Two flashes = stop after 10 minutes.
Three flashes = stop after 15 minutes.
• Indication of saturation of the metal grease filters :
After 200 hours use, one quick flash of the LED 1 will indicate that you must clean the metal grease
filters. (See chapter on 'Maintenance').
To reset the 200 hours timer back to zero requires the motor and lights must be switched 'OFF'; then and
proceed as follows:
Press the LED button '+' for 3 to 4 seconds and the LED lights 1,2,3, 4 and 5 will flash to confirm the
programme has been reset to zero.
8GB
• Indication of saturation of the active charcoal filter :
After 400 hours use, two quick flash of the LED 1 will indicate that you must replace the active charcoal
filter and clean the metal grease filters. (See chapter on 'Maintenance').
To reset the 400-hour timer the motor and lights must be switched 'OFF'.
Push the LED button '+' for 10 seconds.
One flash of the LED lights 1,2,3,4 and 5 = function is switched 'OFF'.
Two flashes of the LED lights 1,2,3,4 and 5 = function is switched 'ON'.
Instructions for replacing the active charcoal filter are given in the chapter on 'Recycling'.
• Pre-set remote control handset
Your cooker hood is supplied with a deactivated remote control receiver. To use the cooker hood with a
remote control re-programme the hood as follows:
Press the LED button (Lighting) '1' while the motor and lights are switched 'OFF', until the LED lights 1 will
flash to confirm the programme has been activated :
One flash of the LED lights 1 = function is switched 'OFF'.
Two flashes of the LED lights 1 = function is switched 'ON'.
Caution, the remote control handset must be fitted with standard LR03-AAA size 1.5V zinc-carbon alkaline
batteries as illustrated Fig. 7. These batteries should give a long life and constant discharge throughout their
life. These batteries must be disposed of properly and could explode if damaged or exposed to heat.