Positioning the grille and sensor connection:
o Identify where you will place the cooled compartment sensor holder
grille (as per subsequent instructions), verifying that any holes for fixing
the grille or for cable passage will not damage the cooling system,
electrical system or other that can affect correct system operation or
the safety of property and/or persons.
o The grille in Fig. 01 is necessary for supporting and positioning the
sensor on a wall for air temperature detection inside the refrigerated
compartment.
o The grille should be placed as far away as possible from the evaporator
(cooling plate) and about 50mm [1.97in] from the bottom, if possible in
a central position on the wall, see ex. Fig. 02 and Fig. 03. Hole positions
for sensor holder grille installation are already indicated on Cruise
Elegance models for maximum product efficiency.
o To fasten the grille, make two 7mm [0.275in] diam. holes that are 105
mm [4.135in] away from one another, with a depth of approximately
15 mm [0.59in], Fig. 03.
o One part of the sensor cable, Fig. 04, approximately 500-700mm
[19.7-27.5 in], must be wound within the recess formed in the sensor
support, see Fig.05.
o Another hole behind the grille must be made to lead the cable toward
the outside, to then be connected to the compressor control unit. The
maximum distance covered by the length of the cable is approximately
3.0 m [120.0 in].
o The temperature sensor must then be connected to the Secop/Danfoss
control unit on the "C" and "T" pins. The two cables can be connected
in any manner.
-
Positioning and fastening the digital display:
Do not install the display inside the refrigerator.
o Wall display.
•
•
38
If you wish to affix the display to the wall, you must choose the
containing box without edges, see Fig. 06, position it on the wall
where it is to be fastened and mark the two holes on the bottom
of the box on the wall to insert the fastening screws and the
centre of the central hole used for cable passage, see Fig. 06
Use the hole cutter to make a hole with a min. diam. 20 [0.79in]
mm on the panel at the marked central point. This hole will be
ISOTHERM Digital Display