ISOTHERM Digital Display
- Sub-menu Configuration Functions illustration:
o PRO [Battery protection level]
o Key:
•
•
•
•
•
•
TAB.01
Cut-Out, switch-off voltage
Cut-In, switch-on voltage
Full Speed, voltage at which the system enters into maximum
cooling power function
Battery saving level
Low,
Shown on the Battery Protection display.
BATTERY PROTECTION
Cut-out
Comp.
off
- - -
9.9
- - -
- - -
10.4
- - -
- - -
11.3
- - -
Medium,
12Vdc
Full
speed /
Cut-in
Over-
Comp.
cooling
on
thresh-
old
11.2
12.4
11.7
12.9
12.5
13.7
High
24Vdc
Cut-out
speed /
Cut-in
Comp.
Comp.
off
on
21.6
23.0
22.6
24.0
24.2
25.6
Full
Over-
cooling
thresh-
old
24.1
25.2
26.8