3. USER INSTRUCTIONS
3.1 ELECTRONIC WATER HEATERS (WITHOUT PERMANENT PILOT LIGHT)
ATTENTION: WHEN THE UNIT IS WORkING, THE TEMPERATURE NEAR THE PEEPHOLE MAY BE HIGH.
Prior checks
1.
Make sure hot water taps are turned off.
2.
Turn on the gas to water heater stopcock that is located where gas is supplied to the appliance.
3.
Check that the 1.5 V batteries are correctly installed according to polarity (+ and -) and the safety seal has been removed.
4.
Check that they are sufficiently charged for the water heater to function.
3.2 Control panel
1
DISPLAY SYMBOLS
Flame Symbol: flashes when the burner is running and is not displayed when the heater is off.
EE: appears when security is activated by temperature limit.
Battery Symbol: appears when load is low on battery.
Battery symbol flashing:
Display Blank: Heater off
vERY IMPORTANT
IT IS RECOMMENDED THAT THE INSTALLATION'S STOPCOCk IS TURNED OFF WHEN THE UNIT IS NOT BEING USED
FREqUENTLY.
IT IS STRICTLY FORBIDDEN TO MAkE ANY INTERvENTION ON THE PART OF THE USER IN THE SEALED DEvICES.
Manual selection of Burner Power
To ignite the appliance, turn the gas knob from the position
The gas knob allows you to select the water heater power, minimum ( ) or maximum ( ), and intermediate positions according
to the hot water intensity required. Turn the gas knob to the
temperature is too high, for example in summer or if a small volume of not very hot water is required, turn the knob to the position
(small flame), reducing the power (and gas consumption) almost by half.
Temperature selection
With the Temperature Selector you can easily gauge the water temperature by turning the selector to the right to achieve a higher
temperature, or to the left to obtain less hot water.
Hot Water Service
• Once the previous settings have been selected, the water heater will start the process; turning on the hot water tap will auto-
matically generate continuous sparks through its ignition electrode and directly light the burner.
• All the electronic models have an ionisation probe, which is immersed in the flame to control it.
• If for any reason an issue has occurred in the gas circuit and the probe does not detect the flame's presence, the ignition
electrode will automatically generate sparks for a few seconds to ignite the burner; in the event that the water heater does
not turn on, it will be out of service.
• You must remove the cause or element that prevents the gas from reaching the water heater, for example if the stopcock has
been inadvertently turned off, worn out gas cylinder, etc.
• The water heater block is deactivated by turning on and off the hot water tap;
3
2
to one of the 2 minimum or maximum positions.
position (large flame), the unit heats the water at full power. If the
cod. 30902370 - Rev. 01 - 11/2017
1. Gas knob
2. temperature selector
3. LCD
EN
31