SYMPTOM
POSSIBLE
CAUSE(S)
CORRECTIVE
ACTION
Motor will not start
1, Low voltage
1. Check power line for proper voltage
2, Open circuit in motor or loose
2, Inspect all lead connections on motor for loose or
connections
open connection
3. Thermal overload protector activated
2. Push thermal overload button to reset
1. Short circuit in line cord or plug
Motor will not start;
fuses blown or circuit
breakers are tripped
Motor fails to develop full
power (power output of
motor decreases rapidly
with decrease in voltage
at motor terminals)
Motor overheats
Motor stalls
(resulting in blown
fusesor trippedcircuit
breakers)
Machine slows down
while operating
Abrasive belt runsoff top
wheel
2. Short circuit in motor or loose
connections
3, Incorrect fuses or circuit breakers in
power line
4. Thermal overload protector activated
1. Power line overloaded with lights,
appliances and other motors
2. Undersize wires or circuits too long
3. General overloading of power
company's facilities
4. V-belt tension not correct
1. Motor overloaded
2. V-belt tension not correct
1. Short circuit in motor or loose
connections
2. Low voltage
3. Incorrect fuses or circuit breakers in
power line
4. Motor overload
Applying too much pressure to workpiece
Not tracking properly
1. Inspect line cord or plug for damaged insulation and
shorted wires
2. Inspect all lead connections on motor for loose or
shorted terminals or worn insulation on wires
3. Install correct fuses or circuit breakers
4, Push thermal overload button to reset
1. Reduce the load on the power line
2. Increase wire sizes, or reduce length of wiring
3. Request a voltage check from the power company
4. Replace V-belt
1. Reduce load on motor
2. Replace V-belt
1. inspect connections in motor for loose or shorted
terminals or worn insulation on lead wires.
2. Correct the low line voltage conditions
3. Install correct fuses or circuit breakers
4. Reduce load on motor
Ease up on pressure
See operation, "Replacing Abrasive Belt"