Adapting
microwave blower
18
4. Drill ¥" (9,5 mm) holes at "A", "B" and "C"
()
CAUTION:
Wear safety goggles when drilling holes in the cabinet bottom.
5. Cut out the 2" (50,8 mm) hole at "D". This hole is for the power supply cord.
Note:
If the cabinet is metal, use the nyion grommet around the opening to protect
the cord.
6. Cut out the shaded area "E" using a saber or keyhole saw.
1. Remove and save the screws holding the blower motor and the blower plate. Lift
up the blower plate and put it aside.
2. Carefully pull out the blower unit and rotate 90° so that fan blade openings are
facing out the top of the microwave
3. Place the blower unit back into the opening.
CAUTION:
Do not pull or stretch the blower unit wiring. Make sure the
wires are not pinched, and that they are properly secured.