CAUTION!
Storage and Transportation of the Generator: (See Fig 21)
•
Remove any debris that has collected on the generator and around the muffler and controls. Use a vacuum cleaner to
pick up loose debris. If dirt is caked on, use a soft bristle brush.
•
Inspect air cooling cylinder fins and flywheel fan. Remove any debris if obstructed.
•
For short-term storage, start generator once every 7 days.
•
For long-term storage, add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system
and carburetor.
•
Store ina sheltered location and use a protective cover to suitable from dust.
Engine Long Term Storage:
•
Remove the spark plug and pour about 1 teaspoon of 10W30 Engine oil into the spark plug hole. Reinstall the spark plug.
With the ON/OFF switch in the OFF position pull the recoil starter cord several time to coat the cylinder walls with oil.
Slowly pull the recoil Starter until you feel the engine build compression (When you feel resistance). Leave the Engine in
•
this state as this will prevent any corrosion on the cylinder walls if stored for a long period of time.
Consult your local hazardous waste management in your area for the proper way to dispose
of used fuel.
Fig 21
MAINTENANCE
21