Before you store the air compressor,
make sure you do the following:
1.
Review the "Maintenance"
section on the preceding pages
and perform scheduled
maintenance as necessary.
2.
Set the On/Auto/Off
lever to
"OFF" and disconnect
electrical
supply.
3.
Close the globe valve.
4.
Remove the air tool or accessory.
5.
Open the globe valve and allow
the air to slowly bleed from the
air tank until tank pressure is
approximately
20 psi.
6.
Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of air tank.
Risk of Bursting.
Water will
condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture and possible
serious personal injury.
7.
After the water has been drained,
close the drain or drain valve.
NOTE: If drain valve is plugged,
release all air pressure.
The valve
can then be removed, cleaned, and
reinstalled.
8.
Protect the air hose from
damage (such as being stepped
on or run over).
D30091
22- ENG