- Press and hold the buttons
- Turn the control wheel to display
- The display flashes to indicate a memory slot (01 to 10).
- Turn the control wheel to select the memory slot containing the settings to be recalled. Validate by pressing the button
QUICK LOAD « q.L. »
The Quickload is a JOB reminder mode outside welding. This mode is possible in MMA.
JOB reminders are made by briefly pressing and releasing the SWITCH of the remote control via a dedicated remote control.
E.g.: if JOB 2, 5, 7 and 10 have been created and the user has entered the number 7, then the recalled JOBs will be 2, 5 and 7.
When the mode is activated, the first JOB is recalled and displayed at the HMI (in the example: JOB 2 and display «J.02»).
If unlocked, the HMI behaves with the specificities:
- the HMI displays «J.XX» continuously as well as the parameters (welding process, Pulse, electrode type,...).
- The cycle is accessible and modifiable (the JOB is out of adjustment (*)),
- The menus are accessible and can be modified. Ex :
- JOB 5, out of adjustment, SAVE IN / JOB 5, the JOB is overwritten with the new parameters and taken into account.
- JOB 5, out of adjustment, SAVE IN / JOB non-existent, it will be taken into account in the current q.L. if and only if this new JOB X is lower than the number
of the JOB entered.
- The JOB reminder is inactive when navigating through the welding cycle or one of the two menus.
(*) A JOB is disturbed by HMI action (welding parameter, JOB recall...), welding is allowed with the new settings. If a JOB recall is performed, then the first
JOB in the series is recalled.
VOLTAGE REDUCING DEVICE (VRD)
The voltage reducing device (or VRD) reduces the assigned no-load voltage to a level not exceeding 35V when the resistance of the external welding circuit
exceeds 200Ω The reaction time is less than 300ms.
By default, the voltage reducer device is disabled. In order to activate it, the user must open the product and follow the following procedure:
- Switch off and disconnect the product from the network
- Set the switches as below:
ON
1
2
3
4
• When the product is switched on, the device is active and the «VRD» LED on the keypad lights up.
REMOTE CONTROL
The remote control operates in TIG mode and in MMA.
ref. 045699
Connection
1- Plug the remote control into the connection at the back of the machine.
2- The machine will detect automatically the remote control and open a selection menu:
Foot pedal selection.
Remote control with potentiometer selection.
3- The selection of the type of remote control is made using the wheel, the validation is made using the
4- The LED (FIG-2, n°14) switches on.
22
IMS 220E FV CEL
and
for 3 seconds.
. Validate by pressing the button
1
2
3
4
VRD
0
0
1
1
NO (by default)
0
0
0
0
YES
G
F
A
B
E
D
C
External view
appears, release the buttons.
.
D
045682
C
B
045675
A
Electric diagram according to remote control type.