adjusted on the "moon" position (min). As for the adjustment pattern, please refer to the
testing pattern. Time-Delay is added continually: When it receives the second induction
signals within the first induction, it will restart to time from the moment.
MANUAL OVERRIDE FUNCTION:
1. Sensor mode > Stay on. Now switch wall switch OFF-ON, OFF-ON twice within
3seconds. The sensor will now hold your light ON continuously just likes a normal light.
2. Stay on > Sensor mode(The following either method is ok)
1).Switch your wall switch OFF, then switch ON after 0.3 seconds.
2). If the light left ON (not change the sensor to sensor mode by hand), the sensor itself
will also automatically return to the sensor mode after 8 hours.
CONNECTION: Warning. Danger of death through electric shock! Must be installed by
professional electrician Disconnect power source. Cover or shied any adjacent live
components. Ensure device cannot be switched on. Check power supply is
disconnected. Loosen the screw on the bottom and unload the bottom. Pass the power
wire through the hole with gasket in the bottom. Connect the power wire into
connection-wire column according to the connection-wire diagram. Fix the bottom with
inflated screw on the selected position (refer to the figure). Install back the sensor on the
bottom, tighten the screw and then test it. Note: you can cut the plastic cover whatever
shape you want and make different detection range. (refer to right figure)
CONNECTION-WIRE DIAGRAM: (See the right figure)
TEST: Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob
clockwise on the maximum (sun).
Switch on the power; the sensor and its connected lamp will have no signal at the
beginning. After Warm-up 30sec, the sensor can start work .If the sensor receives the
induction signal, the lamp will turn on. While there is no another induction signal any
more, the load should stop working within 10sec±3sec and the lamp would turn off.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than
3LUX, the sensor would not work and the lamp stop working too. If the ambient light is
less than 3LUX (darkness), the sensor would work. Under no induction signal condition,
the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work! If the lamp is more than 60W, the distance between lamp
and sensor should be 60cm at least.
SOME PROBLEM AND SOLVED WAY:
The load does not work: a. Please check if the connection of power source and load
is correct. b. Please check if the load is good. c. Please check if the settings of working
light correspond to ambient light.
The sensitivity is poor: a. Please check if there is any hindrance in front of the detector
to affect it to receive the signals. b. Please check if the ambient temperature is too
high. c. Please check if the induction signal source is in the detection field. d. Please
check if the installation height corresponds to the height required in the instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field. b. Please check if the
time delay is set to the maximum position c. Please check if the power corresponds
to the instruction.
PL
Czujnik ruchu na podczerwień
Gratulujemy zakupu nowego czujnika oraz dziękujemy za zaufanie. Jest to produkt
wysokiej jakości, który został wyprodukowany, przetestowany i zapakowany
z najwyższą starannością. Przed przystąpieniem do instalacji produktu zapoznaj się
z instrukcją obsługi, ponieważ długa, niezawodna i bezproblemowa obsługa będzie
zagwarantowana tylko wtedy, gdy urządzenie zostanie odpowiednio zamontowane
i zastosowane.
SPECYFIKACJA:
Zasilanie: 220-240V/AC
Obszar detekcji: 360°
Częstotliwość: 50-60Hz
Temperatura pracy: -20/+40°C
Czujnik oświetlenia: <3-2000 LUX
Wilgotność: <93% RH
Działanie: Czujnik potrafi rozpoznać dzień i noc: użytkownik może dostosować stan
roboczy w różnych warunkach oświetlenia. Może pracować w dzień i w nocy, kiedy jest
ustawiony w pozycji "słońce" (max). Może pracować w świetle otoczenia mniejszym
niż 3LUX, gdy jestustawiony w pozycji "3" (min). Wzór regulacji, znajduje się na
schemacie. Opóźnienie czasowe dodawane jest w sposób ciągły: Po odebraniu drugich
sygnałów indukcyjnych w ramach pierwszej indukcji, wznawia się od nowa.
Sterowanie ręczne - działanie: 1. Tryb czujnika > Pozostań włączony
Teraz wyłącz przełącznik ścienny OFF-ON, OFF-ON dwa razy w ciągu 3 sekund.
Czujnik będzie teraz utrzymywał ciągłe światło.
2. Pozostań włączony > tryb czujnika (następujące metody są w porządku)
1). Wyłącz przełącznik ścienny, a następnie włącz go po 0,3 sekundy.
2). Jeśli światło pozostało włączone (nie zmieniaj ręcznie na tryb czujnika),
czujnik sam również automatycznie powróci do trybu czujnika po 8 godzinach.
MCE243
Opóźnienie czasowe: min. 10sek +/- 3sek.
max. 30min. +/- 2min
Wysokość instalacji: 2.2m-6m
Prędkość detekcji ruchu: 0.6~1.5m/s
Obciążenie max.
2000W
1000W
Dystans detekcji: max. 20m (<24°C)