Connecting and Grounding

The controller warms up during operation, and should therefore be installed on a non flammable surface only.
Connect wires in indicated order 1 2 3 4 5 6 7 to avoid any installation faults
To avoid any damaging voltage on the wires, first connect the wire to the controller, then to the load, to the battery or to the panel.
Minimum recommended wire size: 4 mm²
Make sure the wire length between battery and controller is as short as possible
Be aware that all negative wires of CIS-N-MPPT-LED 85/15 are connected together and therefore have the same electrical potential. If any
grounding is required further to the casing, always do this on the negative wires.
Grounding of the casing is done by the grounding post on the left side.
Maximum cable length from charge controller to LEDs: < 2m
Function
Positive wire LED output
Negative wire LED output
Negative battery terminal
Positive battery terminal
Negative panel terminal
Positive panel terminal
Input for PIR motion sensor
www.phocos.com
Wire size (cross section)
AWG 20 (0.5 mm
2
)
AWG 20 (0.5 mm
2
)
AWG 13 (2.5 mm
2
)
AWG 13 (2.5 mm
2
)
AWG 13 (2.5 mm
2
)
AWG 13 (2.5 mm
)
2
AWG 24 (0.25 mm
2
)
Color
Red
Blue
Black
Red
Black
Yellow