Puller Operation (cont'd)
Wire Pulling up to 1750 lb (7.8 kN) with
Secondary Capstan (cont'd)
• If the continuous operating limit of the puller is
exceeded in low speed mode, the yellow lights
illuminate.
The red light illuminates at 1750 lb to indicate that the
maximum operating limit of the puller has been reached.
The circuit breaker (or current limiting) may shut down
the puller before or shortly after the red light illuminates.
MAIN
SECONDARY
6000
1750
5400
1575
4800
1400
4200
1225
3600
1050
3000
875
2400
700
1800
525
1200
350
600
175
0
0
PULL FORCE (LBS)
PULL FORCE (LBS)
LOW
HIGH
LOW
HIGH
SPEED
SPEED
SPEED
SPEED
DOUBLE TAP
DOUBLE TAP
FOOT SWITCH
FOOT SWITCH
TO CHANGE
TO CHANGE
THE SPEED
THE SPEED
High Speed
Greenlee / A Textron Company
MAIN
SECONDARY
6000
1750
5400
1575
4800
1400
4200
1225
3600
1050
3000
875
2400
700
1800
525
1200
350
600
175
0
0
PULL FORCE (LBS)
PULL FORCE (LBS)
LOW
HIGH
LOW
HIGH
SPEED
SPEED
SPEED
SPEED
DOUBLE TAP
DOUBLE TAP
FOOT SWITCH
FOOT SWITCH
TO CHANGE
TO CHANGE
THE SPEED
THE SPEED
MAIN
SECONDARY
6000
1750
5400
1575
4800
1400
4200
1225
3600
1050
3000
875
2400
700
1800
525
1200
350
600
175
0
0
PULL FORCE (LBS)
PULL FORCE (LBS)
LOW
HIGH
LOW
HIGH
SPEED
SPEED
SPEED
SPEED
DOUBLE TAP
DOUBLE TAP
FOOT SWITCH
FOOT SWITCH
TO CHANGE
TO CHANGE
THE SPEED
THE SPEED
Low Speed
7. Make sure all nearby personnel are not standing in
line with or close to the pull rope. The right angle
sheave on the G6 Turbo should be used to allow the
operator to stand off to the side as required.
8. Position yourself so that you can see the force
gauge indicator lights. Refer to the table below.
Force Gauge Indicator Lights
State of
Pulling Force (lb)
Force Lights
Green
Green flashing
Yellow
Red
9. Grasp the tailing end of the rope. Apply a slight
amount of tailing force.
10. Start the puller by pressing and holding down the
foot switch.
11. Tail the rope, allowing the spent rope to accumulate
on the floor between the operator and the puller.
12. When the pull is complete, turn the puller OFF.
Tie off the rope and anchor the cable.
38
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
G6 Turbo
Duty Cycle
0–1200(low)
Continuous
0–600(high)
600-700(high)
Change to low
5 ON/10 OFF
1200-1575(low)
Over 1575
STOP