BASIC
AiR COMPRESSOR
COMPONENTS
The basic components
of the air compressor are the electric
motor, pump, pressure switch and tank (see Fig. 1).
The electric motor (see A) powers the pump.
TOPS senses both temperature and current, providing more
complete motor overload protection than a magnetic starter,
which senses only current. If TOPS senses an overload condition,
it will automatically shutdown the compressor. Allow 10-15
minutes for the unit to cool down, then press the reset button on
the motor to restart the compressor.
The pump (see B) compresses the air and discharges it into
the tank.
The tank (see C) stores the compressed
air.
The pressure switch
(see D) shuts down the motor when
the tank reaches a pre-set "cut-out" pressure. As compressed
air is used and the tank drops to a pre-set "cut-in" pressure, the
switch restarts the motor automatically, and the pump resumes
compressing air.
A
Fig. 1
ASSEMBLING
THE COMPRESSOR
This compressor was shipped with oil in the pump
crankcase. Check oil before operating the air
compressor, see Check Oil under Maintenance.
1,
Unpack the air compressor.
Inspect the unit for damage. If
the unit has been damaged in transit, contact the carrier
and complete a damage claim. Do this immediately
because there are time limitations to damage claims.
The carton should contain:
•
air compressor
•
operator/parts
manual
2.
Check the compressor's
serial label to ensure that you
have received the model ordered, and that it has the
required pressure rating for its intended use.
3.
Locate the compressor according to the following
guidelines:
d,
problems with lubrication, motor starting and freezing
of water condensation.
Remove the compressor from the shipping pallet and
place it on the floor or a hard, level surface. The
compressor must be level to ensure proper
lubrication of the pump and good drainage of the
moisture in the tank.
_k_he
shipping
pallet is not designed as a
base for an operating compressor.
Operating
the
compressor while it is on the pallet will void your
warranty.
e,
To prevent damage to tank and pump, the tank must be
shimmed so the pump is level within 1/8" per lineal foot
maximum to distribute oil properly. Fasten to floor and
NEVER force tank feet to floor without shims when
tightening. We also recommend the use of vibration
pads (094-0137) under tank feet (E).
4.
Connect an air hose (not included) to the compressor.
a.
For optimum performance, locate the compressor close
to the power panel, as specified in ELECTRICAL
POWER REQUIREMENTS,
and as close as possible to
the place where the air wilt be used. This ensures
maximum power to the compressor and maximum air
pressure to the tool. If both of these conditions
cannot be met, it is better to locate the compressor
close to the power panel, and use a longer air hose
to reach the usage area.
b
The flywheel side of the compressor must be at least
12 inches (31 cm) from any wall or obstruction, in a
clean, well-ventilated
area, to ensure sufficient air
flow and cooling.
c.
In cold climates, locate the compressors
in a
heated building when not in use. This will reduce
200-2924
Fig. 2