EN
The thermostat is locked at the factory, allowing only the set point to be adjusted.
To do this, press the "Set" button, after the set value starts blinking, get to the
desired value with the "" ▲" and " ▼" buttons and press the "Set" key again to set
the value.
The temperature shown on the display is the equipment's internal temperature.
The equipment's noise level is less than 70dB.
Note: The equipment's difference in temperature (difference between maximum and
minimum permissible temperature) is set at 3°C at the factory for the refrigerated counters
and backbar coolers, in models BRS, BRG, BPP, BPG, and FGB, the difference is 4° C, and in
models ARV 36; ARV 66, ARV 150, ARV 350, and ARV 450 the difference is 2° C.
When fully loading the cabinet, it is possible for the alarm to go off after 2 hours if
it has not reached the set temperature, and "Hi" is visible in the display. Press the
"mute" button to turn the alarm off and wait 12 hours for the temperature to
stabilize. If the set temperature has not been reached within this time, please
contact our technical service.
The following messages may appear on the thermostat:
Message
To switch off, press the ON/OFF button (information "OFF" on the display,
equipment off) or disconnect the plug from the mains. Wait 10 minutes before
turning the equipment back on.
36
Operating Message
E0
E1
L0
HI
DF
OFF
Dor
ENS
Description
Ambient Probe Failure
Defrost Probe Failure
Low Temperature Alarm
High Temperature Alarm
Defrosting in progress
Standby
Open Door
Energy Saving Mode