8.1. REPAIR GUIDE
Internal fan does not work
Temperature below the limits
LED lights do not light up
Light does not turn off
If the malfunction continues after these checks, technical assistance should be
requested from your authorized dealer.
Please indicate the type of malfunction, type of appliance, serial number, and date
of purchase (invoice). The serial number and type of appliance are described on the
equipment information label (normally located inside the equipment, on the side).
In case of need for accessories or spare parts, you should also request them from
your authorized dealer, always mentioning the equipment data described above.
Note: For the protection of persons and property against direct/ indirect contacts, the use
of a differential protection of the power outlet directly to this equipment with a trip
sensitivity of 300 mA is mandatory
44
Led light flashing
Does not reach the temperature, but stops and starts
Suction line ice
It is cold, it does not reach the temperature
Possible cause / Repairs
Fan wires off /Check connection
Incorrect wire in the thermostat
Door open (door open alarm/ close the door and see door
micro connection)
Faulty fan/ Replace fan
Faulty Digital thermostat relay/ Replace digital thermostat
Temperature of evaporator above 10ºC, fan off/ Wait for
equipment to cool down
Fan stuck/ Check fan position
Set Point temperature / Check settings
Wrong thermostat connections / Check connections
Safety thermostat/ See position
Glass door Thermostat/ Press AUX
Opaque door/ Close door open door
Incorrect transformer wires/ Check Connections
Faulty transformer/ Replace transformer
Faulty Led lights / Replace led lights
Too much gas/Check gas charge