INSTA LLAiTION
INSTRUCTIONS
Connecting
Elecfric
Dryers
(conf.}
USA only
_WARNENG
• Connect the power cord to the terminal
block.
Connect each power cord wire to the terminal
block
screw that has the same colored
wire. For example,
connect
the black power cord wire to the terminal
block screw with the black wire. Failure to follow
these instructions
may result in a short, overload,
fire or death.
• Grounding
through
the neutral
conductor
is
prohibited
for: (1) new branch-circuit
installations,
(2) mobile
homes,
(3) recreational
vehicles, and
(4.) areas where local codes prohibit
grounding
through
the neutral
conductor.
Four-wire connection for electric dryers:
Power cord
• A 4-wire connection
is required for all mobile
and
manufactured
home installations,
as well as all new
construction
after January 1, 1996.
• A UL-listed strain relief is required.
1. Remove the terminal
block access cover on the upper
back of the dryer. Install a UL-listed strain relief into
the power cord through-hole;
then thread a UL-listed,
30 A, 240 V, 4-wire, #10 AWG-minimum
copper
conductor
power cord through
the strain relief.
. Use a :30 A, 240 V, UL-listed power cord with
#10
AWG-minimum
copper
conductor
and closed loop or
forked terminals with upturned
ends.
2. Transfer the dryer's ground wire from behind the
green ground
screw to the center screw of the
terminal
block. Attach the two hot leads of the power
cord to the outer terminal
block screws. Attach the
white neutral wire to the center terminal
block screw.
Attach the power cord ground
wire to the green
ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal
block access cover.
Hot
Neutral
(Black)
(White)
l il,
Screw
_'_L_,L_-_IF_
/'
__
White Wire
I
@
_
moved
from
I
I I__UL-Listed
_
Strain Relief
4% 2;dowor/
Cord