Overflow Tube
Coupling
Nuts
Tapered
Gaskets
Drain
Tee
Ell
3. Install the Tubing
Slide a coupling nut, then gasket onto the overflow tube.
Slide a coupling nut, then gasket onto the drain ell.
Align the overflow tube and drain ell with the tee. Align the tee
following the illustration for your style of installation.
Insert the tubes completely into the tee. If necessary cut the
overflow tube to the correct length.
Align the tubes and tighten the nuts.
Tighten the strainer body into the drain ell by inserting the
handle of a pliers into strainer body and gently twisting
clockwise.
Face the drain ell tube toward the front of the receptor.
Remove any excess sealant.
Secure the strainer plate to the strainer body using the provided
screw.
Kohler Co.
Screw
Strainer
Plate
5
112746-2-AC