8 E600 CONTROL BOARD
8.1 Technical specifications
Supply voltage (V ~ / Hz.)
Power supply to accessories (Vdc)
Accessories max. load (mA.)
Operating ambient temperature (°C)
Quick-fit connector
Operating logics
Terminal-board connections
Courtesy light timer (min.)
8.2 E600 board components
J1
Low voltage inputs/accessories terminal board
J2
Quick-fit connector for receivers XF433 or XF868
J3
230V power supply input terminal board
J4
Connector for transformer primary winding
Courtesy light terminal-board
J5
J7
Connector for transformer secondary winding
J8
Motor output connector
J12
Battery module connector
Radio signal programming push-button
OPEN A
OPEN B
Radio signal programming push-button
OPEN
OPEN push-button
SETUP
SET-UP push-button
Programming dip-switch
DS1
LD1
Signalling LED: OPEN input
LD2
Signalling LED: STOP input
LD3
Signalling LED: FSW input
Signalling LED: SET UP cycle
LD4
LD5
LED signalling memory-storage: radio channel OPEN A
LD6
LED signalling memory-storage: radio channel OPEN B
8.3 Terminal-boards and connectors
Description
Command device with N.O. contact
OPEN A
(see chap. OPERATING LOGICS)
Device with N.C. contact which stops the
STOP
automated system
Negative for OPEN A and STOP devices
Closing safety device with N.C. contact (see
FSW
chap. OPERATING LOGICS)
OPEN COLLECTOR 24 Vdc 100 mA. output for
LAMP
flashing lamp
Negative for powering safety accessories (FAIL
-TX FSW
SAFE function)
Negative for powering accessories
+24 Vdc for powering accessories
8.4 DS1 Programming dip-switches
No. Function
1 Fail Safe
2 Anti-crushing sensitivity
3 Not used
4 Carriage speed
230 / 50
24
200
-20 / +55
for receiver boards XF433 /
XF868 and battery module
Automatic / Semiautomatic
Open/Stop/Safety devices/Fail-
safe/Flashing lamp 24 Vdc
2
Connected device
OFF
ON
Enabled
Not enabled
Low
High
/
/
High
Low
LD1
LD2
LD3
J1
DS1
LD5
LD6
Fail Safe
If activated, it enables the photocell operating test before every
movement.
Operating logics
For doors with an irregular movement, it reduces the sensitivity of
the anti-crushing device to prevent unwanted action by it.
8.5 Operating logics
Logic A (automatic)
Status
Open (pulse)
Opens and closes
CLOSED
after pause time
OPENING
No effect
OPEN IN
Resumes counting of
PAUSE
pause time (1)
CLOSING
Reverses motion
LOCKED
Closes
Logic E (semi-automatic)
Status
Open (pulse)
CLOSED
Opens
OPENING
Locks
OPEN
Closes
CLOSING
Reverses motion
LOCKED
Closes
(1) Prevents closing if pulse is maintained.
(2) Prevents closing and/or opening if pulse is
maintained.
10
J8
LD4
J7
J2
J12
J4
J5
J3
Fig. 25
Stop
Fsw
No effect (2)
No effect
Locks (2)
No effect (1)
Resumes counting of
Locks (1)
pause time (1)
Locks (2)
Reverses motion
No effect (2)
No effect (1)
Stop
Fsw
No effect (2)
No effect
Locks (2)
No effect (1)
No effect (2)
No effect (1)
Locks (2)
Reverses motion
No effect (2)
No effect (1)