Priming And Adjustment Of Oil Pump - Ecoflam MAIOR P 60 AB Manual De Instrucciones

Quemador de gasoleo
Ocultar thumbs Ver también para MAIOR P 60 AB:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
Use only the suitable box wrench provided for this operation to remove the nozzle, taking care to not damage
the electrodes. Fit the new nozzle with the same care.
Note: Always check the position of electrodes after having replaced the nozzle (see illustration). A wrong posi-
tion could cause ignition troubles.
SUNTEC AS 67 B
4
5
V
P
SUNTEC
SUNTEC
SUNTEC
3
1
2
SUNTEC AN 77
3
6
P
V
SUNTEC
SUNTEC
SUNTEC
3
2
1
Start the burner and check the pump feeding pressure. In case the pump priming does not take place during
the first prepurging, with a consequent, subsequent lock-out of the burner, rearm the burner's lock-out to
restart, by pushing the button on the control box. If, after a successful pump priming, the burner locks-out
after the prepurging, due to a fuel pressure drop in the pump, rearm the burner's lock-out to restart the bur-
ner. Do never allow the pump working without oil for more than three minutes. Note: before starting the
burner, check that the return pipe is open. An eventual obstruction could damage the pump sealing device.
NOZZLE CLEANING AND REPLACEMENT
6 mm

PRIMING AND ADJUSTMENT OF OIL PUMP

SUNTEC AJ 6 C-C
5
3
6
4
3
4
VERIFY:
5
- That piping system is perfectly sealed;
- That the use of hoses is avoided whenever is possible (use copper
pipes preferably);
- That depression is not greater than 0,45 bar, to avoid pump's cavi-
tation;
- That check valve is suitably designed for the duty;
The pump pressure is set at a value of 12 bar during the testing of
3
burners. Before starting the burner, bleed the air in the pump throu-
gh the gauge port. Fill the piping with light-oil to facilitate the
pump priming.
11
420010985800 Maior P 60/80/120 AB CV
3
SUNTEC
SUNTEC
SUNTEC
1 - INLET
2
1
2 - RETURN
3 - BLEED AND PRESSURE GAUGE PORT
4 - VACUUM GAUGE PORT
5 - PRESSURE ADJUSTMENT
6 - TO NOZZLE
3,5 mm