OPERATION MANUAL AND INSTRUCTIONS
Display Legend
1) Auto power off enable/disable function indicator
2) Wind speed indication (SLOW <5 m/s; FAST >5m/s)
3) Measured or set value
4) Flow measurement unit indication
5) Wind velocity measurement unit indication
6) Flow area measurement unit indication
7) Maximum (MAX) or minimum (MIN) value indication
8) Low battery indicator
9) Flow area setting
10) Flow measurement function
11) Wind velocity measurement function
12) Data hold enable function
Techncial data
Wind speed
(VEL)
Measuring
range:
Range
0.80 ~30.00
m/s
30.00~40.00
1.40~108.00
Km/h
108.00~144.0
1.30~98.50
ft/s
98.50~131.20
0.80~58.30
knots
58.30~77.70
0.90~67.20
mil/h
67.20~90.00
78~5900
ft/m
5900~7874
Resolution
Accuracy
0.01
± 2%
0.01
just for reference
0.01
± 2%
0.01
just for reference
0.01
± 2%
0.01
just for reference
0.01
± 2%
0.01
just for reference
0.01
± 2%
0.01
just for reference
1
± 2%
1
just for reference
EN