Descargar Imprimir esta página

NEFF D 4618 Instrucciones De Uso Y Montaje página 22

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
Installation Instructions:
Important information
Old appliances are not worthless
rubbish. If they are disposed of in an
environment-friendly manner, valuable raw
materials can be recovered for use again.
Before you dispose of an old appliance,
make sure that it has been rendered
inoperative.
Your new appliance was protected on
its way to you by the packaging. None of
the materials cause pollution to the envi-
ronment and all can be recycled for use
again. Please help to protect the
environment and dispose of the packaging
in an environment-friendly manner.
You can obtain information about the best
method disposing of old appliances and
packaging from your dealer or local
municipal council.
The extractor hood can be used in
either exhaust-air or recirculating mode.
Always mount the extractor hood over
the centre of the hob.
Minimum distance between electric
hob and bottom edge of extractor hood:
430 mm, Fig. 1.
Additional notes concerning gas
cookers:
When installing gas hotplates, comply
with the relevant national statutory
regulations (e.g. in Germany: Technische
Regeln Gasinstallation TRGI).
The relevant regulations and installation
notes provided by the manufacturer of the
gas cooker must be observed in all cases.
The extractor hood may be installed
next to only one full-height cupboard or
high wall. Gap to be at least 50 mm.
22
The installation of the extractor hood
above gas cooking devices, at a
minimum height of 650 mm – Fig. 1 – is
permitted provided that the following
nominal heat loads (Hs) are not exceeded:
Gas cookers
Load of one hotplate
Load of all hotplates
Load of the oven
Gas hobs
Load of one hotplate
Load of all hotplates
Gas glass-ceramic hotplate
The data on nominal heat loads do not
apply to gas glass-ceramic hotplates.
Be sure to observe the instructions
provided by the manufacturer of the
hotplate.
Solid-fuel cookers
The maximum nominal heat loads and
the minimum distance are the same as
for gas cookers.
Installation of the extractor hood over a
solid-fuel burner which could constitute a
potential fire hazard (e.g. due to flying
sparks) is only permitted if the burner is
equipped with an enclosed, non-
removable cover and all country-specific
regulations are observed. This restriction
does not apply to gas cookers and gas
hobs.
The smaller the gap between extractor
hood and hob, the greater the likelihood
that rising steam will cause condensation
to form on the hood.
max. 03.0 kW
max. 08.3 kW
max. 03.9 kW
max. 03.9 kW
max. 11.3 kW

Publicidad

loading

Este manual también es adecuado para:

D 4644D 4654