Circuit Breakers; Draining Tanks; Draining Recovery Tank; Draining Solution Tank - Nobles Speed Scrub 2601 Manual Del Operador Y Piezas

Limpiador automático de cepillo cilíndrico
Ocultar thumbs Ver también para Speed Scrub 2601:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION

CIRCUIT BREAKERS

The machine is equipped with (4) resettable circuit
breakers to protect machine from damage.
If circuit breakers should trip, the breakers will not
reset immediately upon tripping. Determine cause,
allow motor to cool then manually reset circuit breaker
button.
The brush motor circuit breakers may trip due to
excessive brush pressure. Reduce brush pressure.
Brush motor circuit breakers (25 amp) are located
near the charger plug.
The main (10 amp) and drive/vacuum (35 amp) circuit
breakers are located at rear of machine (Figure 18).
FIG. 18

DRAINING TANKS

FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.

DRAINING RECOVERY TANK

When finished scrubbing or when refilling solution
tank, recovery tank should be drained and cleaned.
12
Home
Home
Find... Go To..
Find... Go To..
ATTENTION: If recovery tank is not drained
before refilling, foam or water will enter float
shut-off screen and vacuum motor damage will
result.
1. Remove drain hose from holder, position hose
over floor drain and twist off drain hose cap. To
completely drain recovery tank, hinge open tank
and flip up tank support stand to rest tank on
(Figure 19).
NOTE: If using a bucket to drain machine, do not use
same bucket for filling solution tank. This will prevent
possible solution line clogs.
FIG. 19
2. Clean recovery tank after each use. Use a hose to
rinse out tank. Be careful not to spray water into
float shut--off screen.
3. Replace drain hose cap tightly after draining.

DRAINING SOLUTION TANK

To drain leftover cleaning solution from solution tank,
perform the following steps:
1. Pull the clear hose off hose barb at rear of
machine and drain solution into floor drain or
bucket (Figure 20).
FIG. 20
2. Rinse out solution tank and solution flow system
with clean water after each use. This will prevent
clogging due to chemical buildup.
Speed Scrub 2601 Cylindrical Brush (12- -02)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1002193

Tabla de contenido