Troubleshooting
You can rectify minor faults yourself with the help
of the following overview.
If in doubt, please consult the authorized custom-
er service.
Risk of injury
Always switch off the appliance and pull out the
mains plug before care and maintenance work.
Warning
Repair works may only be performed by the au-
thorized customer service.
Appliance does not start
Check whether the voltage indicated on the
type plate corresponds to the voltage of the
socket.
Check the power cable for damage.
Pressure does not build up in the appliance
Check the setting at the spray lance.
Evacuate air from the appliance: Switch on
the appliance when the HP hose is not con-
nected and allow it to run until the water
which discharges from the HP outlet is free of
bubbles. Then connect the HP hose again.
Clean the filter in the water supply connec-
tion: This can be easily removed using flat-
nose pliers.
Check all supply lines to the HP pump for
leaks or blockages.
Strong pressure fluctuations
Clean the high-pressure nozzle: Remove dirt
and debris from the nozzle bore with a nee-
dle and rinse through with water towards the
front.
Check the volume of incoming water.
HP pump leaking
Slight leakage from the HP pump is normal.
If the leakage increases contact the author-
ized customer service.
No detergent infeed
Select the low-pressure setting for the spray
lance.
Clean the filter of the detergent suction hose.
Check the DT suction hose for kinks.
Specifications
Power connection
Voltage
1~50 Hz
Connected load
Mains fuse (slow-blow)
Protective class
Water connection
Max. feed temperature
Min. feed volume
Feed pressure
Performance data
Working pressure
Max. permissible pressure
Water flow rate
Detergent flow rate
Recoil force of trigger gun
Hand-arm vibration
(ISO 5349)
Sound pressure level
L
(EN60704-1)
pA
Sound power level
L
(2000/14/EG)
WA
Dimensions
Length
Width
Height
Weight
Subject to technical modifications!
230 V
2,0 kW
10 A
I
40 °C
10 l/min
0,2 - 1,2 MPa
12 MPa
13 MPa
7,5 l/min
0,3 l/min
15 N
2,0 m/s
2
77 dB(A)
92 dB(A)
300 mm
340 mm
830 mm
12,7 kg
13