Dimensions for 27"
Wall-Mounted
Units
Single Oven 27"
24°
(610mm) ¢ -
ania")
(718mm)
27 1/16"
| (687mm)
tt
min. 43/4" (121mm)
max. 38° (64mm)
y o
na
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4" space between the side of the
oven and the wall/door.
For oven support, install 2x4's extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box must be installed either above or below
the unit. If the conduit box is installed below the unit, a 2"
diameter hole or space is required between the back wall
and the right rear of the 2x4 supports.
The cabinet base must be flat and capable of supporting a
weight of at least 193 Ibs (87 kg).
Double Oven 27"
21/2"
p+ (648mm)
|
"Hig
wm,
G1 3/6"
(630mm)
gia"
(1314mm)
4gaia"
(1264mm)
.
min. 434" (121mm
J
7 max. 171/4"(438mm)
4K
2378" (606mm)
99"
(5
Pa
(559mm)
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4" space between the side of the
oven and the wall/door.
For oven support, install 2x4's extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box must be located above the unit to facilitate
connecting and servicing.
The cabinet base must be flat and capable of supporting a
weight of at least 361 Ibs (164 kg).