Descargar Imprimir esta página

Thermador M301 Manual De Instrucciones página 8

Ocultar thumbs Ver también para M301:

Publicidad

Idiomas disponibles

Idiomas disponibles

Dimensions for 30"
Wall-Mounted
Units
Single Oven 30"
ete"
asver|
(Fiemm)
mre
aging"
(738mm)
min, 43/4" (424mm)
max. 38" 964mm)
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4" space between the side of the
oven and the wall/door.
For oven support, install 2x4's extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box must be installed either above or below
the unit. If the conduit box is installed below the unit, a 2"
diameter hole or space is required between the back wall
and the right rear of the 2x4 supports.
The cabinet base must be flat and capable of supporting a
weight of at least 212 Ibs (96 kg).
English 6
Double Oven 30"
21/2"
(724mm)
ty
aga"
~ (755mm)
ie:
51a"
5130/4"
(134mm)
-
"aga
(1264mrn)
| min. 404" (121m,
l .. max. 171/4"(438mm)
a
4
237/86" (606mm)
dl
22" (559mm)
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4" space between the side of the
oven and the wall/door.
For oven support, install 2x4's extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box must be located above the unit to facilitate
connecting and servicing.
The cabinet base must be flat and capable of supporting a
weight of at least 390 Ibs (177 kg).

Publicidad