English
Remaining battery
indicator lamp
Display panel
Lights ;
The battery remaining power is over 75%.
Lights ;
The battery remaining power is 50%–75%.
Lights ;
The battery remaining power is 25%–50%.
WARNING
Be sure to turn off the switch and pull out the
battery before doing any inspection or
maintenance.
1. Inspecting the application tool
Continued use of a dull or damaged application tool
will result in reduced cutting efficiency and may cause
overloading of the motor. Replace the application tool
with new one as soon as excessive abrasion is noted.
2. Check the Screws
Loose screws are dangerous. Regularly inspect them
and make sure they are tight.
CAUTION
Using this power tool with loosened screws is
extremely dangerous.
3. Inspection of terminals (Tool and battery)
Check to make sure that swarf and dust have not
collected on the terminals.
On occasion check prior, during and after operation.
16
Remaining battery
indicator switch
Fig. 16
Table 5
MAINTENANCE AND INSPECTION
Lights ;
The battery remaining power is less than
25%.
Blinks ;
The battery remaining power is nearly
empty. Recharge the battery soonest
possible.
Blinks ;
Output suspended due to high temperature.
Remove the battery from the tool and allow it
to fully cool down.
Blinks ;
Output suspended due to failure or
malfunction. The problem may be the battery
so please contact your dealer.
As the remaining battery indicator shows somewhat
differently depending on ambient temperature and battery
characteristics, read it as a reference.
CAUTION
Do not give a strong shock to the display panel
or break it. It may lead to a trouble.
CAUTION
Remove any swarf or dust which may have
collected on the terminals.
Failure to do so may result in malfunction.
4. Check for dust
Dust may be removed with a soft cloth or a cloth
dampened with soapy water.
Do not use bleach, chlorine, gasoline or thinner, for
they may damage the plastics.